TryBuildCalc

10mm Aggregate Calculator (Small Coarse Aggregate Quantity Estimate)

Estimate 10mm aggregate quantity.

Inputs

Use this calculator when you know concrete volume and mix ratio. If you know the concrete element dimensions, switch to Dimensions mode and the calculator will first calculate concrete volume.

Need aggregate for road base, driveway, GSB, WMM, or area × depth? Use the Aggregate Coverage Calculator or Aggregate Weight Calculator.

Input Mode

ℹ️Selecting aggregate size updates the default ratio, aggregate part, and bulk density.

ℹ️For a 1:2:4 concrete ratio, the aggregate part is 4.

ℹ️Typical value is 1.54 for concrete and PCC aggregate estimation.

ℹ️Used to estimate weight from calculated loose aggregate volume.

Cost

Enable Cost Estimation?

For 1.000 of concrete at a 1:2:4 ratio, you need approximately 0.924 (32.6 cft) of 10mm aggregate — 1.48 tons.

Order Summary — Theoretical vs. Order Quantity

TheoreticalOrder Quantity
Volume0.8800.924 m³ (32.6 cft)
Weight1,408 kg1,478 kg (1.48 tons)

Theoretical = before wastage. Order Quantity = after your 5.0% wastage allowance. Round up to a supplier-friendly quantity — approx. 1.0 or 1.5 tons.

Volume & Mix Details

Wet volume: 1.000

Dry volume (×1.54): 1.540

Ratio used: 1:2:4, aggregate part 4

Assumptions Used

Aggregate size: 10mm | Bulk density: 1,600 kg/m³ | Actual weight varies by aggregate size, stone type, moisture, and compaction.

10mm Coarse Aggregate VisualizationConcrete Mix Ratio: 1 : 2 : 4Cement14%Sand29%Aggregate57%Recommended 10mm Aggregate QuantitySmaller stone particles0.92432.63 cft | 1.478 tonsRound order: 1 m³ or 1.5 tonsDiagram simplified for clarity (not to scale)

Looking for the verification checklist, reference tables, tips, or common mistakes?See the complete Aggregate Calculator.

10mm aggregate quantity estimate

10mm aggregate is commonly used in thin sections, dense reinforcement zones, precast elements, and smaller concrete elements where larger aggregate can't pass through bar gaps or fill thin formwork.

This page preselects 10mm aggregate and its default bulk density (1600 kg/m³, typically denser than 20mm/40mm due to tighter packing).

  • 10mm aggregate suits thin sections, congested reinforcement, and precast work.
  • Default bulk density: 1600 kg/m³ — denser packing than larger aggregate sizes.
  • Check bar spacing and section thickness against the checklist's max-aggregate-size rules before finalizing size.

Step-by-step aggregate quantity calculation method

Aggregate quantity calculation starts with the required wet concrete volume. In Direct Volume mode, you enter that concrete volume directly. In Dimensions mode, the calculator first converts length, width, and depth/thickness into concrete volume. The calculator then converts wet volume into dry material volume, applies the selected mix ratio, calculates the aggregate share, and converts loose aggregate volume into approximate weight using bulk density.

For road base, driveway layers, GSB, WMM, or area × depth aggregate-only work, use the Aggregate Coverage Calculator or Aggregate Weight Calculator. This calculator is for concrete mix-ratio aggregate estimation.

Step 1 - Determine required concrete volume

Concrete volume is the finished wet concrete volume required for slabs, beams, columns, PCC, foundations, or other construction works. Enter it directly, or calculate it from dimensions.

Direct Volume Mode: Wet Volume = Entered Concrete Volume

Dimensions Mode: Wet Volume = Length × Width × Depth / Thickness

Step 2 - Convert wet volume to dry volume

Dry volume factor accounts for voids between aggregate particles, sand bulking, compaction, and practical site handling losses. For concrete and PCC estimation, a dry volume factor of 1.54 is commonly used.

Dry Volume = Wet Volume × Dry Volume Factor

Step 3 - Calculate aggregate share from mix ratio

The aggregate ratio part is divided by the total mix ratio parts to calculate the loose aggregate volume required for the selected concrete mix.

Aggregate Volume = (Aggregate Part ÷ Total Parts) × Dry Volume

Step 4 - Convert aggregate volume to approximate weight

Bulk density converts loose aggregate volume into approximate aggregate weight. The default density changes automatically when you select 10mm, 20mm, or 40mm aggregate, and it can be adjusted for local material conditions.

Aggregate Weight = Aggregate Volume × Bulk Density

Step 5 - Apply wastage allowance

Wastage allowance accounts for practical site losses during transport, unloading, storage, handling, and placement.

Final Quantity = Base Quantity × (1 + Wastage %)

Worked Example

This example walks through your current inputs above, using the same steps as the Formula section.

Input Values Used

InputValueWhy it is used
Concrete volume1 m³Sets the wet concrete volume to convert
Mix ratio / aggregate part1:2:4, part 4, ×1.54Splits dry volume into the aggregate share
Density / wastage1,600 kg/m³, 5% wastageConverts volume to weight and adds a buffer for site losses

Step 1 — Volume

CalculationSubstitutionResult
Wet volume1 m³1.000
Dry volume1.000 × 1.541.540

Step 2 — Aggregate Quantity

CalculationSubstitutionResult
Aggregate volume (theoretical)4 / 7 × 1.5400.880
Aggregate weight (theoretical)0.880 × 1,6001,408 kg
With 5% wastage0.880 × 1.050.924 m³ (1.48 tons)

Therefore, plan for approximately 0.92 (32.6 cft) — 1.48 tons — of 10mm aggregate for this pour.

Disclaimer: This calculator provides approximate results for planning and estimation purposes only. Actual requirements may vary based on site conditions, materials, workmanship, and local building regulations. Always consult a qualified engineer, architect, or construction professional before making final decisions.

FAQ

Use 10mm aggregate for thin sections, precast elements, or where reinforcement is congested and larger aggregate can't pass through the bar spacing — confirm against the maximum-aggregate-size rule for your section.
Smaller aggregate particles pack more densely (less void space between particles) than larger ones, giving 10mm aggregate a typically higher bulk density (~1600 kg/m³) than 20mm (~1550 kg/m³).