Roof Truss Quantity & Installation Verification Checklist

Essential Checklist+

Complete these critical checks before approving the work or proceeding to the next construction stage.

βœ“13 Inspection Points
βœ“4 Verification Categories
βœ“Truss Design Inputs+
  • Building span and length confirmed from actual field measurements or plans, not assumed
  • Roof pitch entered matches the actual design intent, not a rough guess
  • Truss spacing matches the roof sheathing/decking span rating and the actual roof load for this project
  • Local building code edition, wind/seismic zone, and snow load confirmed before finalizing
βœ“Truss Engineering & Design+
  • Confirmed this calculator does NOT replace an engineered, stamped truss design β€” a real truss order/design was obtained separately
  • Truss placement diagram from the manufacturer matches the actual roof plan and this takeoff's count
  • Girder trusses (trusses that carry other trusses, e.g. at a valley or opening) identified and engineered separately
  • Damaged or incorrectly-cut trusses are never modified in the field without engineering approval
βœ“Bracing & Installation+
  • Temporary erection bracing planned and installed as each truss is set β€” before it's left unsupported
  • Permanent bracing (web member bracing, continuous lateral bracing) installed exactly per the truss designer's drawing
  • Truss-to-wall connectors (hurricane ties/truss anchors) rated for the site's actual wind/seismic uplift requirement
βœ“Installation & Code Compliance+
  • Permit and framing inspection requirements confirmed before roof sheathing covers the trusses and their bracing
  • Wide spans, unusual loads, or any non-standard condition reviewed by the truss designer or a structural engineer
Full QC Checklist+

Verify truss design inputs, truss engineering/design, bracing and installation, and installation/code compliance.

βœ“20 Inspection Points
βœ“4 Verification Categories
βœ“Truss Design Inputs+
  • Building span and length confirmed from actual field measurements or plans, not assumed
  • Roof pitch entered matches the actual design intent, not a rough guess
  • Truss type selected matches the actual roof design (common, scissor, attic, mono, etc.)
  • Truss spacing matches the roof sheathing/decking span rating and the actual roof load for this project
  • Calculation confirmed to represent one clear-span truss run at a time
  • Local building code edition, wind/seismic zone, and snow load confirmed before finalizing
βœ“Truss Engineering & Design+
  • Confirmed this calculator does NOT replace an engineered, stamped truss design β€” a real truss order/design was obtained separately
  • Truss placement diagram from the manufacturer matches the actual roof plan and this takeoff's count
  • Girder trusses (trusses that carry other trusses, e.g. at a valley or opening) identified and engineered separately
  • Damaged or incorrectly-cut trusses are never modified in the field without engineering approval
  • Gable end truss type (vertical-stud vs. step-down ladder) confirmed against the actual gable overhang detail
βœ“Bracing & Installation+
  • Temporary erection bracing planned and installed as each truss is set β€” before it's left unsupported
  • Permanent bracing (web member bracing, continuous lateral bracing) installed exactly per the truss designer's drawing
  • Truss-to-wall connectors (hurricane ties/truss anchors) rated for the site's actual wind/seismic uplift requirement
  • Gable end truss fastening and any required L-bracing/stiffener bracing installed per the truss drawing
  • Crane lift plan (if used) confirmed against actual truss weight, span, and site access β€” not assumed
βœ“Installation & Code Compliance+
  • Roof sheathing, underlayment, and roofing material planned and estimated separately
  • Attic/roof ventilation (soffit, ridge, or gable vents) planned to match the actual truss heel and ridge detail
  • Permit and framing inspection requirements confirmed before roof sheathing covers the trusses and their bracing
  • Wide spans, unusual loads, or any non-standard condition reviewed by the truss designer or a structural engineer
Inspection Notes+
Use the latest approved drawings, specifications, and site measurements.
Complete all critical checks before proceeding to the next work stage.
Record deviations and confirm rectification where required.