Portable AC BTU Calculator (SACC Sizing, Single- vs. Dual-Hose)

Size your portable AC's real SACC capacity instantly.

Inputs

Unit Type
Calculation Mode
ft²

ℹ️Measured floor area of the single, enclosed room this unit will cool — not a multi-room open floor plan.

ft

ℹ️Energy Star's sizing chart assumes an 8 ft ceiling. Taller rooms hold more air and may need a larger unit than shown.

ℹ️Very sunny rooms need +10% capacity; heavily shaded rooms need 10% less, per Energy Star's guidance.

Is This a Kitchen?

ℹ️Adds 600 BTU for each person beyond a baseline of 2 who regularly uses this room.

ℹ️Dual-hose units draw makeup air from outdoors and typically deliver a higher share of their ASHRAE rating as real SACC cooling than single-hose units.

Recommended SACC Rating

7,000 BTU/hr

Match against the unit's SACC rating, not its marketed ASHRAE BTU number

Look for SACC, not ASHRAE BTU. A dual-hose portable AC delivering this much real cooling is often labeled with an inflated ASHRAE BTU figure around 8,100-10,300 BTU— check the EnergyGuide/DOE label for the model's actual SACC rating rather than trusting the marketed number alone.

Room & Conditions

Unit type: Portable

Room area: 300 sq ft

Sun exposure: Average / Typical

Kitchen: No

Occupants: 2

Sizing Breakdown

Base capacity (area only): 7,000 BTU/hr

After adjustments: 7,000 BTU/hr

Recommended nominal size: 7,000 BTU/hr

Est. ASHRAE-label range (Dual-Hose): 8,100-10,300 BTU

Portable Air ConditionerRoom area → adjustments → recommended BTU300 sq ft roomPortableUnitExhaust hose → window kitRecommended SACC7,000 BTU/hrDual-Hose~8,100-10,300 ASHRAE BTUIllustrative — not to scale. Planning estimate only.

Looking for the verification checklist, reference tables, tips, or common mistakes?See the complete Window/Portable AC BTU Calculator.

Portable air conditioner SACC sizing

Portable air conditioners are dual-rated — a legacy ASHRAE BTU figure that manufacturers often headline in marketing, and a DOE-mandated SACC (Seasonally Adjusted Cooling Capacity) that reflects real delivered cooling after accounting for the exhaust hose's infiltration effect. This calculator's recommended BTU figure is the room's real cooling need, which should be matched against a portable unit's SACC rating, not its ASHRAE number.

This page defaults to a 300 sq ft room with a dual-hose portable unit — edit the inputs above to match your actual room and preferred hose type.

Window/Portable AC Formula: How Is It Determined?

Sizing starts from Energy Star's official area-to-BTU chart, applies three independent adjustments, then rounds up to the next real, purchasable unit size — with an additional SACC/ASHRAE step for portable units only.

Base Capacity from Room Area

Area = Room Length × Room Width, or your entered known area

Base BTU/hr = Energy Star sizing chart lookup for your room's floor area (assumes an 8 ft ceiling)

Energy Star publishes an official chart mapping room floor area directly to a base cooling capacity in BTU/hr, ranging from 5,000 BTU for a 100-150 sq ft room up to 34,000 BTU for a 2,000-2,500 sq ft room. This chart explicitly assumes an 8 ft ceiling — Energy Star gives no official numeric adjustment for taller rooms, only a qualitative note that more capacity may be needed, which this calculator surfaces as a warning rather than an invented multiplier. You can enter a known area directly, or switch Calculation Mode to compute it from the room's length and width instead — both feed the exact same chart lookup.

Sun, Kitchen, and Occupancy Adjustments

Sun adjustment = Base BTU × (+10% very sunny, 0% average, −10% heavily shaded)

Kitchen adjustment = +4,000 BTU flat, if the room is a kitchen

Occupancy adjustment = +600 BTU × occupants beyond a baseline of 2

Adjusted BTU = Base BTU + Sun Adjustment + Kitchen Adjustment + Occupancy Adjustment

These three adjustments come directly from Energy Star's own published sizing guidance, applied on top of the area-based base capacity. Sun exposure and kitchen use both address real, sustained heat gain sources the floor area alone doesn't capture; the occupancy adjustment accounts for body heat from more than the typical 2 people the base chart assumes.

Recommended Nominal Size

Recommended BTU = next available nominal unit size on the sizing chart ≥ Adjusted BTU

The adjusted BTU figure is rounded UP to the next real, purchasable unit size on Energy Star's own chart — never down — since a unit smaller than the actual need runs continuously without ever comfortably reaching the target temperature during peak heat.

Portable Units Only: Estimated ASHRAE-Label Range

Estimated ASHRAE low = Recommended BTU ÷ hose type's maximum SACC/ASHRAE ratio

Estimated ASHRAE high = Recommended BTU ÷ hose type's minimum SACC/ASHRAE ratio

Portable units are dual-rated: SACC (Seasonally Adjusted Cooling Capacity, the DOE-mandated figure reflecting real delivered cooling) and the older ASHRAE BTU figure, which doesn't account for the exhaust hose's infiltration effect and is typically higher. Since SACC is typically 55-71% of ASHRAE for single-hose units and 68-86% for dual-hose units, this calculator shows the estimated ASHRAE-label range you should expect on a unit that actually delivers your recommended real (SACC) capacity — a published estimate range, not a precise per-model conversion, since DOE does not publish one fixed ratio. Always check the specific model's EnergyGuide/DOE label for its actual SACC rating.

Worked Example

This example walks through your current inputs above, using the same steps as the Formula section.

Input Values Used

InputValue
Unit typePortable
Room area300 sq ft
Ceiling height8 ft
Sun exposureAverage / Typical
Kitchen / occupantsNo / 2
Hose typeDual-Hose

Step-by-Step Calculation

StepCalculationResult
Base capacity (300 sq ft)Energy Star chart lookup7,000 BTU/hr
Sun adjustment (Average / Typical)7,000 × 0%+0 BTU/hr
Kitchen adjustmentNot a kitchen+0 BTU/hr
Occupancy adjustment0 extra × 600+0 BTU/hr
Adjusted BTUSum of the above7,000 BTU/hr
Recommended nominal sizeRound up to next chart size7,000 BTU/hr
Est. ASHRAE-label range (Dual-Hose)7,000 ÷ hose ratio bounds8,100-10,300 BTU

Therefore, this 300 sq ft room needs a 7,000 BTU/hr portable air conditioner, matched against SACC (roughly 8,100-10,300 BTU if shopping by the ASHRAE label instead).

Disclaimer: This calculator provides approximate results for planning and estimation purposes only. Actual requirements may vary based on site conditions, materials, workmanship, and local building regulations. Always consult a qualified engineer, architect, or construction professional before making final decisions.

FAQ

The recommended figure is your room's real cooling need, matched against a portable unit's SACC rating. The estimated range below it is roughly what ASHRAE-labeled BTU figure to expect on a unit that actually delivers that much SACC — since many portable ACs are still marketed by the larger, less meaningful ASHRAE number.
Yes — SACC accounts for the exhaust hose's infiltration and heat leakback effect, which the older ASHRAE test doesn't. A portable unit's SACC rating is typically 55-86% of its ASHRAE figure, depending mostly on whether it's single-hose or dual-hose.