TryBuildCalc

Lintel CalculatorConcrete, steel & shuttering estimator for door/window openings

Calculate concrete, steel, and shuttering quantity for an RCC lintel over a door or window opening.

Basic Dimensions

ℹ️Clear width of the door/window opening, not the lintel's own length.

ℹ️Commonly 150 mm minimum on each side for typical openings — confirm against your project's structural drawing.

ℹ️A lintel normally spans the full wall thickness.

ℹ️Rule of thumb: span ÷ 10 to span ÷ 12, with a practical minimum of ~150 mm.

ℹ️Set to more than 1 if several openings share the same lintel size.

Material Details

Reinforcement

Include Top (Hanger) Bars?

ℹ️Commonly 100-150 mm centre-to-centre for residential lintels.

Cost

Enable Cost Estimation?

For 1 lintel of 1.50 m (4.92 ft) each (span + bearing), you need approximately 0.054 of concrete and 4.9 kg of reinforcement steel.

Concrete

Concrete volume: 0.054 (1.92 cft)

Cement: 0.4 bags

Sand: 0.023 (0.81 cft)

Aggregate: 0.046 (1.61 cft)

Steel Reinforcement

Main (Bottom) Bars: 2 × 10 mm

Stirrups: 11 × 8 mm

Total steel weight: 4.9 kg

Shuttering

Soffit area: 0.35

Side faces: 0.45

Total contact area: 0.79 (8.6 sqft)

Bar TypeDiameterCount / SpacingCutting LengthTotal LengthWeight
Main (Bottom) Bars10 mm21.450 m2.90 m1.79 kg
Stirrups8 mm150 mm c/c (11/lintel)0.720 m7.92 m3.13 kg

Assumptions Used

Lintel length = clear span + bearing on both sides | Steel weight: d² ÷ 162 (kg/m) | Stirrup hook allowance: 10 × diameter per end | Concrete dry volume factor: 1.54

Unsure about bearing length or depth for your opening span? Lintel Design Guide →

Lintel Over Opening (Elevation)Span: 1.2 mBearingBearingBearing (each side): 150 mmDepth: 150 mm

Diagram simplified for clarity (not to scale). Illustrative only.

Looking for the verification checklist, reference tables, tips, or common mistakes?See the complete Lintel Calculator.

Complete RCC lintel material estimate

This page gives the full combined result for an RCC lintel — concrete volume and cement bags, main/hanger bar and stirrup reinforcement, and shuttering (formwork) contact area — from one set of opening span, bearing length, lintel size, and reinforcement inputs.

It's the same calculator behind every other lintel material variant on this site, just without a single material pre-selected — useful when you need concrete, steel, and shuttering together for one opening, in one pass.

  • Lintel length = opening span + bearing length on both sides, not just the opening width.
  • Concrete, steel, and shuttering are calculated from the same geometry, so they stay consistent with each other.
  • An optional cost estimate can be turned on from the same form.

How Is the Lintel Quantity Calculated?

The calculation happens in four parts — lintel length, concrete quantity, steel reinforcement, and shuttering area — then an optional cost estimate on top.

Step 1 — Lintel Length

Lintel Length = Opening Span + (2 × Bearing Length)

The lintel must rest on solid wall beyond the opening on both sides — its true length is always longer than the opening it spans.

Step 2 — Concrete Volume

Wet Volume = Length × Width × Depth (per lintel, × count for multiple openings)

Dry Volume = Wet Volume × 1.54

Cement Bags = Cement Volume ÷ 0.0347 m³/bag (50 kg bags)

Dry volume accounts for the voids between aggregate particles that disappear once the concrete is mixed and compacted. The dry volume is then split into cement, sand, and aggregate using the selected mix ratio, and the wastage percentage is applied once to the final quantities.

Step 3 — Steel Reinforcement

Bar Length (each bar) = Lintel Length − (2 × Concrete Cover)

Stirrups per Lintel = ⌊(Lintel Length ÷ Spacing)⌋ + 1

Stirrup Cutting Length = 2 × (Width − 2×Cover + Depth − 2×Cover) + Hook Allowance (2 × 10 × diameter)

Unit Weight (kg/m) = Diameter² ÷ 162

Main and top bars run the length of the lintel minus end cover; stirrups are closed loops sized to the concrete section minus cover on each side, with a hook allowance added at both ends to close the loop.

Step 4 — Shuttering Area

Soffit Area = Width × Length

Side Area = 2 × Depth × Length

Total Contact Area = (Soffit + Side Area) × Count

Shuttering supports the underside (soffit) and both vertical faces of the lintel until the concrete gains enough strength to be self-supporting — the wall itself typically forms the end shuttering, so no separate end panels are counted.

Worked Example

This example walks through your current inputs above, using the same steps as the Formula section.

Input Values Used

InputValueWhy it is used
Opening span1.2 mFixes the clear opening width the lintel must bridge
Bearing length (each side)150 mmAdds the extra length resting on solid wall on both sides, setting the true lintel length
Lintel width × depth230mm × 150mmSets the concrete cross-section and the shuttering side area
Mix ratio / wastage1:1.5:3, 5% wastageConverts wet volume to cement bags and adds a buffer for site losses
Cover / bar diameter / spacing25 mm cover, 10 mm main × 2, 8 mm stirrups @ 150 mmSets bar cutting length (span minus cover) and stirrup count/size
Number of openings1Multiplies every final quantity for identical repeated lintels

Step 1 — Lintel Length

CalculationSubstitutionResult
Opening span1.2 m1.200 m
Bearing (each side)150 mm0.150 m
Lintel length1.200 + 2 × 0.1501.500 m (4.92 ft)

Step 2 — Concrete

CalculationSubstitutionResult
Wet volume1.50 × 230mm × 150mm × 10.052
With 5% wastage0.052 × 1.050.054 m³ (0.4 bags)

Step 3 — Steel

Bar TypeSubstitutionWeight
Main (Bottom) Bars2 × 1.450 m × 10²÷1621.79 kg
Stirrups11 × 0.720 m × 8²÷1623.13 kg
Total steelSum of all rows4.92 kg

Therefore, 1 lintel of 1.50 m each needs 0.054 of concrete, 4.9 kg of steel, and 0.79 of shuttering.

Disclaimer: This calculator provides approximate results for planning and estimation purposes only. Actual requirements may vary based on site conditions, materials, workmanship, and local building regulations. Always consult a qualified engineer, architect, or construction professional before making final decisions.

FAQ

Yes — this is the full combined calculator. All three are computed from the same lintel geometry and shown together in the result card, with a full bar schedule and worked example.
A lintel must rest on solid wall beyond the opening on both sides — that extra length is the bearing length. Lintel length = opening span + bearing on the left + bearing on the right, so it's always longer than the opening itself.