Door Lintel CalculatorLintel estimator for door openings

Calculate concrete, steel, and shuttering quantity for an RCC lintel over a door or window opening.

Basic Dimensions

ℹ️Clear width of the door/window opening, not the lintel's own length.

ℹ️Commonly 150 mm minimum on each side for typical openings — confirm against your project's structural drawing.

ℹ️A lintel normally spans the full wall thickness.

ℹ️Rule of thumb: span ÷ 10 to span ÷ 12, with a practical minimum of ~150 mm.

ℹ️Set to more than 1 if several openings share the same lintel size.

Material Details

Reinforcement

Include Top (Hanger) Bars?

ℹ️Commonly 100-150 mm centre-to-centre for residential lintels.

Cost

Enable Cost Estimation?

For 1 lintel of 1.20 m (3.94 ft) each (span + bearing), you need approximately 0.043 of concrete and 4.0 kg of reinforcement steel.

Concrete

Concrete volume: 0.043 (1.54 cft)

Cement: 0.4 bags

Sand: 0.018 (0.64 cft)

Aggregate: 0.037 (1.29 cft)

Steel Reinforcement

Main (Bottom) Bars: 2 × 10 mm

Stirrups: 9 × 8 mm

Total steel weight: 4.0 kg

Shuttering

Soffit area: 0.28

Side faces: 0.36

Total contact area: 0.64 (6.9 sqft)

Bar TypeDiameterCount / SpacingCutting LengthTotal LengthWeight
Main (Bottom) Bars10 mm21.150 m2.30 m1.42 kg
Stirrups8 mm150 mm c/c (9/lintel)0.720 m6.48 m2.56 kg

Assumptions Used

Lintel length = clear span + bearing on both sides | Steel weight: d² ÷ 162 (kg/m) | Stirrup hook allowance: 10 × diameter per end | Concrete dry volume factor: 1.54

Unsure about bearing length or depth for your opening span? Lintel Design Guide →

Lintel Over Opening (Elevation)Span: 0.9 mBearingBearingBearing (each side): 150 mmDepth: 150 mm

Diagram simplified for clarity (not to scale). Illustrative only.

Looking for the verification checklist, reference tables, tips, or common mistakes?See the complete Lintel Calculator.

Lintel sizing for a door opening

This page is pre-filled with a typical 0.9 m door opening and a 230 mm × 150 mm lintel (matching a standard 230 mm wall thickness) — a common residential internal or external door size.

Door openings are usually narrower than window openings, so bearing length and depth rules of thumb tend to sit at the lower end of their typical range — still worth confirming against the structural drawing, especially where a door opening carries more wall or slab load than usual.

  • Standard door widths (0.75-1.0 m) typically need only the minimum bearing length, commonly 100-150 mm each side.
  • Lintel width should match the wall thickness the door sits in.
  • Edit the span, wall thickness, or reinforcement above to match your actual door opening.

How Is the Lintel Quantity Calculated?

The calculation happens in four parts — lintel length, concrete quantity, steel reinforcement, and shuttering area — then an optional cost estimate on top.

Step 1 — Lintel Length

Lintel Length = Opening Span + (2 × Bearing Length)

The lintel must rest on solid wall beyond the opening on both sides — its true length is always longer than the opening it spans.

Step 2 — Concrete Volume

Wet Volume = Length × Width × Depth (per lintel, × count for multiple openings)

Dry Volume = Wet Volume × 1.54

Cement Bags = Cement Volume ÷ 0.0347 m³/bag (50 kg bags)

Dry volume accounts for the voids between aggregate particles that disappear once the concrete is mixed and compacted. The dry volume is then split into cement, sand, and aggregate using the selected mix ratio, and the wastage percentage is applied once to the final quantities.

Step 3 — Steel Reinforcement

Bar Length (each bar) = Lintel Length − (2 × Concrete Cover)

Stirrups per Lintel = ⌊(Lintel Length ÷ Spacing)⌋ + 1

Stirrup Cutting Length = 2 × (Width − 2×Cover + Depth − 2×Cover) + Hook Allowance (2 × 10 × diameter)

Unit Weight (kg/m) = Diameter² ÷ 162

Main and top bars run the length of the lintel minus end cover; stirrups are closed loops sized to the concrete section minus cover on each side, with a hook allowance added at both ends to close the loop.

Step 4 — Shuttering Area

Soffit Area = Width × Length

Side Area = 2 × Depth × Length

Total Contact Area = (Soffit + Side Area) × Count

Shuttering supports the underside (soffit) and both vertical faces of the lintel until the concrete gains enough strength to be self-supporting — the wall itself typically forms the end shuttering, so no separate end panels are counted.

Worked Example

This example walks through your current inputs above, using the same steps as the Formula section.

Input Values Used

InputValueWhy it is used
Opening span0.9 mFixes the clear opening width the lintel must bridge
Bearing length (each side)150 mmAdds the extra length resting on solid wall on both sides, setting the true lintel length
Lintel width × depth230mm × 150mmSets the concrete cross-section and the shuttering side area
Mix ratio / wastage1:1.5:3, 5% wastageConverts wet volume to cement bags and adds a buffer for site losses
Cover / bar diameter / spacing25 mm cover, 10 mm main × 2, 8 mm stirrups @ 150 mmSets bar cutting length (span minus cover) and stirrup count/size
Number of openings1Multiplies every final quantity for identical repeated lintels

Step 1 — Lintel Length

CalculationSubstitutionResult
Opening span0.9 m0.900 m
Bearing (each side)150 mm0.150 m
Lintel length0.900 + 2 × 0.1501.200 m (3.94 ft)

Step 2 — Concrete

CalculationSubstitutionResult
Wet volume1.20 × 230mm × 150mm × 10.041
With 5% wastage0.041 × 1.050.043 m³ (0.4 bags)

Step 3 — Steel

Bar TypeSubstitutionWeight
Main (Bottom) Bars2 × 1.150 m × 10²÷1621.42 kg
Stirrups9 × 0.720 m × 8²÷1622.56 kg
Total steelSum of all rows3.98 kg

Therefore, 1 lintel of 1.20 m each needs 0.043 of concrete, 4.0 kg of steel, and 0.64 of shuttering.

Disclaimer: This calculator provides approximate results for planning and estimation purposes only. Actual requirements may vary based on site conditions, materials, workmanship, and local building regulations. Always consult a qualified engineer, architect, or construction professional before making final decisions.

FAQ

Commonly 100-150 mm on each side for a standard residential door width (0.75-1.0 m), though this should be confirmed against your project's structural drawing, especially for wider door openings or heavier loads above.
Not necessarily on diameter or stirrup spacing — those depend mainly on load and depth, not opening type. A narrower door span does mean a shorter, lighter lintel overall, but the main bar diameter and stirrup pattern usually follow the same rules of thumb as a window of similar span.