Bathroom Fan CFM Calculator (Bathroom Exhaust Fan Sizing)

Size your bathroom fan instantly.

Inputs

Room Type
sq ft

ℹ️Floor area of the bathroom only.

Separate Shower Stall?

ℹ️A jetted/whirlpool tub is one fixture, not an addition to a separate standard tub.

ℹ️Sets the ASHRAE 62.2/IRC code-minimum floor — 50 CFM intermittent, 20 CFM continuous.

Recommended Bathroom Fan Size

50 CFM

Next standard retail size ≥ 50 CFM raw requirement

Bathroom

Square footage: 50 sq ft

Ventilation type: Intermittent (fan switch)

Fixtures: None beyond toilet

Sizing Method Used

Method: square-footage method (bathroom ≤100 sq ft)

Square-footage method: 50 CFM

Fixture-based method: 50 CFM (reference only)

Raw requirement: 50 CFM

Bathroom Fan CFM EstimateCeiling-mounted exhaust fan50 CFMRecommended fan sizeToiletShowerTubIllustrative — not to scale. Planning estimate, does not model duct losses.

Looking for the verification checklist, reference tables, tips, or common mistakes?See the complete Exhaust Fan / Range Hood CFM Calculator.

Bathroom fan CFM sizing

A bathroom exhaust fan is sized by ONE method — per HVI's own guidance, the square-footage method (1 CFM/sq ft) for bathrooms up to 100 sq ft, or a fixture-based method above that — floored at the ASHRAE 62.2/IRC code minimum for your ventilation type.

This page defaults to a standard 50 sq ft bathroom (well under the 100 sq ft threshold) with no separate shower/tub and intermittent ventilation — edit the inputs above to match your actual bathroom.

Exhaust Fan / Range Hood CFM Formula: How Is It Determined?

Bathroom mode selects ONE sizing method based on room size and ventilation type, per HVI's own guidance — it does not compare methods and take the highest. Kitchen mode compares two independently-sourced methods and uses the higher.

Bathroom Mode

Intermittent, ≤100 sq ft: Raw CFM = max(Bathroom Sq Ft × 1 CFM/sq ft, 50 CFM code minimum)

Intermittent, >100 sq ft: Raw CFM = max(Fixture Method, 50 CFM code minimum)

Fixture Method = 50 (toilet) + 50 (if separate shower) + 50 (if standard tub) or 100 (if jetted tub)

Continuous (any size): Raw CFM = 20 CFM flat

Nominal Fan Size = next standard retail size ≥ Raw CFM, up to 300 CFM

Per HVI's own guidance, the square-footage and fixture-based methods are BOTH intermittent-ventilation rules of thumb, and are alternatives selected by room size — not two methods to compare and take the higher of. A jetted/whirlpool tub counts as one fixture (100 CFM), not an addition on top of a separate standard tub. Continuous ventilation is a flat 20 CFM code-compliant rate, not scaled by room size or fixtures. The raw requirement is rounded UP to a standard retail bathroom fan size (50, 80, 100, 110, 150, 190, 250, or 300 CFM), since bathroom fans genuinely are sold in this common size range across manufacturers (though exact model availability still varies by brand).

Kitchen Mode

Linear-Foot Method = (Width in inches ÷ 12) × 100 (wall) or × 150 (island)

BTU Method (gas only, if entered) = Total BTU Output ÷ 100

Required CFM = max(Linear-Foot Method, BTU Method) when BTU is entered for gas, otherwise Linear-Foot Method alone

Required CFM is reported directly, rounded UP for readability (never down, so the displayed figure never understates the raw requirement), since range hood CFM is NOT standardized into a common retail size ladder the way bathroom fans are. Once the RAW required CFM exceeds 400, IRC M1503.6 may require makeup air — but only when qualifying non-direct-vent, non-mechanically-drafted fuel-burning appliances are inside the home's air barrier; code permits mechanical or passive makeup air, sized to your installed system's actual capacity, not just this estimate. Broan's own guidance treats the linear-foot method as reliable for gas cooktops only up to roughly 60,000 BTU total output — above that, entering the BTU rating is necessary, since a width-only estimate can significantly understate a high-output gas range's true requirement. Broan also recommends additional CFM beyond both methods here for an integrated grill/griddle or a mounting height above the standard ~30in, which this calculator does not model.

Worked Example

This example walks through your current inputs above, using the same steps as the Formula section.

Input Values Used

InputValue
Square footage50 sq ft
Ventilation typeIntermittent (fan switch)
FixturesNone beyond toilet

Sizing Method Used

This bathroom is 50 sq ft (≤100 sq ft), so HVI's square-footage method applies — the fixture-based method below is shown for reference only.

MethodResult
Square-footage method (1 CFM/sq ft, ≤100 sq ft only) — used50 CFM
Fixture-based method (>100 sq ft only)50 CFM
Code minimum (Intermittent (fan switch))50 CFM
Raw requirement50 CFM
Nominal fan size, rounded up50 CFM

Therefore, this bathroom needs a fan rated at approximately 50 CFM.

Disclaimer: This calculator provides approximate results for planning and estimation purposes only. Actual requirements may vary based on site conditions, materials, workmanship, and local building regulations. Always consult a qualified engineer, architect, or construction professional before making final decisions.

FAQ

At 1 CFM per sq ft, a 50 sq ft bathroom needs at least 50 CFM — which also happens to match the intermittent-ventilation code minimum, so a standard 50 CFM fan typically covers it.
A toilet is always assumed present and only factors into the fixture-based method used for bathrooms over 100 sq ft — for a bathroom this size, only the square-footage method applies, so fixtures don't change the result at all.