TryBuildCalc

Land Drain Calculator (Metric) (Stone in m³ and Tonnes, Coil in Metres)

Metric land drain sizing — m³, tonnes, metres of coil.

Inputs

The Trench

Measurement Units

Applies to every dimension on this form — trench lengths in metres, and widths, depths, bedding and overlaps in centimetres. Switching converts the figures already entered rather than reinterpreting them.

▾

ℹ️The single biggest difference between this calculator and every other one. On flat ground the fall has to be dug into the trench, so the outlet end finishes deeper than the inlet end and the dig is a wedge, not a box.

The ground surface is level (or falls less than the drain needs), so the trench floor drops away from it. The outlet end finishes deeper than the inlet end by the full length times the slope. This is the normal case for a wet lawn or a low spot.

Drain Runs

Add a row per straight run. A main with laterals coming into it is best entered as the main plus one row per lateral — each has its own length, depth and fall, and the fabric and pipe are bought per run.

Run 1

m
cm

💡Measured at the inlet end — the outlet end is worked out from the fall.

cm

💡1% is the standard minimum — 1/8 in of drop per foot of run.

%

Pipe

▾

ℹ️Changes the capacity by more than a factor of two at the same fall. The ribbed bore of cheap single-wall coil is the single most common reason a correctly-dug drain still backs up.

The cheap black flexible coil sold for yard drainage. Easy to lay around curves, and hydraulically the worst of the three — its ribbed bore carries barely 40% of what rigid pipe carries at the same fall.

▾

ℹ️4 in / 100 mm covers almost all residential work. Capacity rises with diameter to the power of 8/3, so one size up is nearly three times the flow, not one third more.

▾

ℹ️Every run has to be one continuous length, so the coil or stick count is a cutting problem rather than a total divided by a coil length.

💡Stone laid before the pipe goes in. At least 2 in / 5 cm, so the pipe can be brought to a true grade.

cm

ℹ️The bedding is what lets you set the pipe to an even fall instead of following every dip in the trench floor. It also comes off the stone available above the pipe, which is why the cover figure in the result moves when you change it.

💡Unperforated pipe from the end of the stone to the outlet. Enter 0 if there is none.

m

ℹ️This is what the "add 10% for the outlet" rule on other calculators is standing in for — except it is a different product, not extra of the same one. Perforated pipe outside the trench just puts the water back into the ground you are draining.

▾

ℹ️Solid pipe is a different product from the perforated coil in the trench — you cannot cut unperforated pipe off a perforated coil — so it has its own stock size. It is most often sold in 10 ft sticks.

▾

ℹ️A knitted filter sleeve on the pipe itself. Useful in clean sandy ground; in silty soil it is the layer that blinds first, and once it does the water cannot reach the pipe even though the stone around it is still clear.

▾

ℹ️Every French drain needs somewhere to put the water. Where the outlet ends up is also what limits how deep the trench can be at its far end.

The pipe simply emerges on a bank or in a ditch. The cheapest and most reliable outlet there is — provided the ground actually falls away far enough for the pipe to reach it.

Drainage Stone

▾

ℹ️Open-graded angular stone is what a French drain runs on — it holds its voids open under load. The void ratio shown drives the storage figure in the result.

The usual single-size clean stone specified for UK land drains.

▾

ℹ️Stone is quoted by weight, by loose volume or by the bag depending on the yard — the result shows all three regardless, but the bag count needs to know which bag.

▾

💡Stone that ends up beside the trench rather than in it, plus settlement as it is raked in.

%

Geotextile

▾

ℹ️Decides the width of fabric the trench actually needs. A full wrap has to cover the floor, both walls AND two flaps that fold back over the stone — roughly twice the section a bottom-and-walls lining needs.

The specification that actually keeps a French drain alive. The fabric lines the floor and both walls, the stone goes in, and the two flaps fold back over the top and overlap in the middle so silt cannot enter from any direction.

▾

ℹ️Non-woven needle-punched fabric. 4 oz is the standard residential weight; step up to 6 oz in fine or silty soil, where a lighter fabric blinds sooner.

▾

ℹ️If the wrapped section is wider than the roll, the fabric has to be seamed lengthwise — and every seam is somewhere silt can find its way in. The result will tell you if a wider roll would cover it in one piece.

💡12 in / 30 cm is the standard specification, for both the fold over the stone and any lengthwise seam.

cm

Finishing the Surface

▾

ℹ️A cap comes off the top of the stone, so it reduces the stone you buy and the cover over the pipe at the same time. A soil cap also seals the drain from surface water, which matters if the problem is water standing ON the lawn.

A soil cap so the drain disappears into the lawn. Note this seals the trench to surface water — the drain now only takes what soaks down to it.

cm

💡Grated boxes that let surface water in directly. The usual fix for a drain capped with soil and grass.

💡Soil takes up more room out of the ground than in it — 20-30% for most soils, more for clay.

%

Capacity Check

Check Whether the Drain Copes?

Sizes the water arriving against what the pipe can carry away and what the stone can hold. This is the question a materials list on its own never answers.

💡Everything that sheds water toward the drain — roof, paving, and the slope of ground above it.

▾
▾

ℹ️Sets the runoff coefficient — the fraction of rain that actually runs off rather than soaking in. A roof sheds nearly all of it; sandy turf sheds almost none.

💡Your local short-duration design storm. The reference table further down the page gives typical starting figures.

mm/hr
Rainfall Unit

Cost Estimation

Estimate Cost?

Drainage Stone Needed

12.15

US tons (11.02 tonnes) — 9.48 cu yd / 7.25 cu m loose

Perforated Pipe

98.42

ft (30 m) — 1 x 50 m coil

Excavation

10.59

cu yd (8.1 cu m) in the ground — 13.24 cu yd of spoil to move

The fall is dug into the trench, so the outlet end finishes deeper than the inlet end. That wedge is 1.77 cu yd (1.35 cu m) more dig and stone than a constant-depth estimate — 20% above the 8.83 cu yd a flat calculation would have given you.

Capacity: Comfortable — the design storm delivers 9.6 gpm (0.61 l/s) into a pipe that carries 44.4 gpm full bore at 1%, so it runs at 21.6% of full.

Drainage Stone

Clean Angular 20-40 mm Stone

In the trench: 243.87 cu ft

Order volume (incl. 5% settlement/spillage): 9.48 cu yd

Weight: 12.15 US tons (11.02 tonnes)

Bulk bags: 12 (~2204.6 lb each)

Void space at 40%: 97.55 cu ft — 730 gal (2762 L) held in the stone itself

Pipe

100 mm Corrugated HDPE Drain Tile

Perforated: 98.42 ft (30 m)

Solid to the outlet: 9.84 ft (3 m)

Coils to buy: 1 x 50 m coil, plus 1 x 10 ft stick (rigid) of solid pipe

That is 174.04 ft of pipe bought for 108.3 ft laid — whole coils and sticks, so the cost below is based on what you buy.

Roughness n = 0.024 — full-bore capacity 44.4 gpm at 1%

Geotextile

4oz non-woven, full wrap (burrito)

Section to cover: 9.19 ft (2.8 m) across

Strips: 2 off a 6.56 ft roll, 1 lapped seam

Rolls to buy: 1 x 2 m x 100 m roll

A 12.5 ft x 360 ft full roll — standard drainage roll would cover the same section in one piece and delete all 1 seam.

Trench & Finish

Total run: 98.42 ft (30 m) over 1 run

Excavation: 10.59 cu yd in the ground

Spoil, bulked 25%: 13.24 cu yd

Bedding under the pipe: 3.1 in (8 cm)

Cap: 1.18 cu yd of topsoil and grass over the stone, 3.9 in deep

Fittings: 3 — 1 cap, 1 coupling, 1 outlet grate

Depth Along Each Run

RunLengthFallDepth at inletDepth at outletStone over pipe
Land drain98.43 ft1% — 11.8 in drop29.5 in41.3 in18 in → 29.9 in

Depths are measured from the finished surface. In a dig-to-fall trench the stone cover over the pipe grows toward the outlet, so it is the inlet end that has to satisfy the minimum.

Which Runs Come Off Which Coil

  • Coil 1: 98.43 ft — 65.61 ft left over

Before You Dig

  • Because the ground is flat, the fall has to be dug into the trench: Land drain starts 29.5 in deep and finishes 41.3 in deep, a drop of 11.8 in over its length. That deep end is what decides whether the outlet can daylight at all — check it against the ground you are discharging onto before you start digging, not after.
  • That wedge of extra depth is 1.77 cu yd (1.35 cu m) of dig and stone — 20% more than a constant-depth estimate would have told you to order. It is the single commonest way a French drain takeoff comes up short.
  • Wrapping this trench takes 2 strips of 6.56 ft fabric with 1 lapped seam to make up the 9.19 ft section. A 12.5 ft x 360 ft full roll — standard drainage roll covers the same section in one piece and deletes every one of those seams — each seam is a place silt can find its way in.
  • A topsoil-and-grass cap makes the drain disappear into the lawn, and it also seals it off from surface water. The drain will now only take what soaks down through the soil. If the problem you are solving is water standing ON the lawn rather than in it, leave the stone open to the surface or add a channel or catch basin that feeds the trench directly.
  • The pipe carries the design storm at 21.6% of full bore, and the stone voids hold a further 97.55 cu ft (730 gal) — roughly 76 minutes of the design inflow even if the outlet were blocked entirely. This drain has real margin in it.

Bill of Materials

Main material: 12 bulk bags + recommended tools

+

Computed quantities come from your own runs, trench dimensions and material settings above; the consumables below are general recommendations, filtered to this job — actual needs vary by product, ground conditions and site access.

For Your Job

Clean Angular 20-40 mm Stone

12 bulk bags

9.48 cu yd / 7.25 cu m loose, including 5% settlement and spillage

Find suppliers

100 mm perforated drain pipe

98.42 ft (30 m)

1 x 50 m coil

Find suppliers

100 mm solid (unperforated) outlet pipe

9.84 ft (3 m)

1 x 10 ft stick (rigid)

Find suppliers

4oz non-woven geotextile

1 x 2 m x 100 m roll

2 strips at 9.19 ft across the wrapped section, 1 lapped seam

Find suppliers

100 mm fittings

3 pieces

1 end cap, 1 coupling, 1 outlet grate

Find suppliers

Topsoil and grass over the stone

1.18 cu yd (0.9 cu m)

3.9 in deep over 96.9 sq ft of trench

Find suppliers

Excavated spoil to remove

13.24 cu yd (10.12 cu m) loose

10.59 cu yd in the ground, bulked 25% as it is dug

Find suppliers

General Tools & Consumables

Trenching spade / mattock

String line, pegs and a long spirit level

Laser level or water level (long runs)

site-dependent

Wheelbarrow and a stone rake

Garden hose (for the flow test)

Marker paint and utility locate reference

check first

Pipework

Pipe cutter or fine-toothed saw

Rodent guard / outlet grate

Rodding point or clean-out (long or silty runs)

site-dependent

Geotextile

Landscape staples / fabric pins

Sharp scissors or a hooked utility knife

Extra fabric for lapped seams

Capping & Making Good

Topsoil screen or landscape rake

Grass seed or turf offcuts

site-dependent

Safety

Gloves, eye protection and steel-toe boots

Worth Checking

Catch basin or channel drain

check first

French Drain Diagram

Along the run — 98.4 ft at 1%Ground levelfall 11.8 in29.5 in41.3 inInletOutletfall dug into the trenchAcross the trench — 11.8 in widegeotextile4.4 in pipecapstone11.8 in wide — 3.7 in of stone each side

Long section drawn from your own run: the surface stays level and the floor falls away from it, so the outlet end is genuinely deeper. Vertical scale is exaggerated against horizontal so the fall is visible — a 98.4 ft trench drawn true to scale would be a hairline. Cross-section layers are proportional to their real depths, with a minimum thickness so thin layers stay legible.

Looking for the verification checklist, reference tables, tips, or common mistakes?See the complete French Drain / Land Drain Materials Calculator.

The same drain, measured the way it is sold

Land drain is bought in metric: perforated coil in 60, 80, 100 and 160 mm diameters supplied in 25, 50, 100 and 150 m coils; clean single-size stone at 20-40 mm sold by the tonne or the dumpy bag; geotextile off 1 m, 2 m and 4.5 m rolls. Working in feet and converting at the end is how a coil count ends up one short.

The engineering is identical whichever units you use. The fall still has to be dug into the trench on level ground, so a 30 m run at 1% finishes 300 mm deeper than it starts; the coil still has to be one continuous length per run, so the coils are packed rather than divided; and the geotextile still has to cover the whole wrapped section, which on a 300 mm wide, 750 mm deep trench is over 2 m across.

French Drain Formula

Six steps, in the order the calculator works them out. Every one of them is a step where the common shortcut gives a different answer from the real geometry.

Step 1 — Depth along the run

Depth at the outlet = depth at the inlet + (length x slope)

Mean depth = depth at the inlet + (length x slope) / 2

On ground that already falls, both ends are the same and the mean is simply that depth. On flat ground the fall has to be dug in, and this is where every constant-depth estimate goes wrong.

Step 2 — Excavation (a wedge, not a box)

Trench volume = width x length x mean depth

Spoil to move = trench volume x (1 + bulking %)

The trench is a trapezoidal prism whenever the fall is dug in, so the mean depth — not the depth you typed — is what multiplies out. Soil also takes up more room out of the ground than in it.

Step 3 — Drainage stone

Stone envelope = width x length x (mean depth - cap thickness)

Pipe displacement = pi / 4 x (pipe outside diameter)^2 x length

Stone volume = stone envelope - pipe displacement

Order volume = stone volume x (1 + settlement %)

Weight = order volume x loose density

Void storage = stone volume x void ratio

The pipe occupies space the stone would otherwise fill, and any cap layer comes off the top. Void storage is what the trench itself holds during the peak of a storm.

Step 4 — Stone cover over the pipe (derived, not assumed)

Cover at the inlet = depth at the inlet - cap - bedding - pipe outside diameter

Cover at the outlet = depth at the outlet - cap - bedding - pipe outside diameter

Cover is not an input — you know how deep you are digging, and the cover is whatever is left. It grows toward the outlet, so the inlet end is the one that has to clear the 3 in minimum.

Step 5 — Geotextile, as strips off a roll

Full wrap section = (2 x trench width) + (2 x stone depth) + overlap

Lining only = trench width + (2 x stone depth) + (2 x margin)

Strips = 1 + ceil((section - roll width) / (roll width - overlap))

Rolls = the strip lengths packed into the roll length

The leading 1 matters: the first strip has nothing to lap onto. A full wrap needs roughly twice the width a bottom-and-walls lining does, because of the two flaps that fold back over the stone.

Step 6 — Capacity check

Inflow (cfs) = C x i x A (rational method, A in acres, i in in/hr)

Pipe capacity (cfs) = (1.486 / n) x A x R^(2/3) x S^(1/2) (Manning, full bore)

Usable capacity = pipe capacity x 0.5

Buffer = void storage / inflow

Three separate questions with three separate answers: how much water arrives, how much the pipe carries away, and how much the stone holds while that happens.

Why pipe and roll counts are packed, not divided. Every run has to be one continuous length of pipe, and every fabric strip one continuous piece. Three 60 ft runs off 100 ft coils need three coils, not the two that 180 ÷ 100 suggests — no coil can hold two of them. This calculator packs the lengths into stock rather than dividing, and tells you which runs come off which coil so the count can be checked on site.

Real-World French Drain Calculation Example

This example uses the values you have entered above and follows the same six steps as the formula section. Each table shows the value used, the formula applied, and the result produced.

Input Values Used

InputValueWhy it is used
Land drain98.4 ft long, 11.8 in wide, 29.5 in deep at the inlet, falling 1%Sets the excavation, the stone envelope and the fabric section for this run
Ground profileFlat — the fall is dug into the trenchDecides whether the trench is a wedge or a constant-depth box
Drainage stoneClean Angular 20-40 mm Stone at 94.9 lb/cu ft, 40% voidConverts stone volume into weight, and gives the trench its water storage
Pipe100 mm Corrugated HDPE Drain Tile, roughness n = 0.024Displaces stone, and sets how much water can be carried away
Bedding under the pipe3.1 inLets the pipe be set to a true grade, and comes off the cover above it
Geotextile4oz non-woven, full wrap (burrito), 11.8 in overlapSets the fabric width the trench section actually needs
Cap layerTopsoil and grass over the stone, 3.9 inComes off the top of the stone, reducing both stone and cover
Allowances5% stone settlement, 25% spoil bulkingCovers spillage into the order, and sizing the spoil to be carted away
Design storm2,152.8 sq ft at C = 0.55, 0.79 in/hrThe water the drain has to cope with

Step 1 — Depth along the run

The fall is added to the inlet depth to find how deep the trench finishes, and the mean of the two ends is what the excavation multiplies out by.

CalculationFormula / SubstitutionResult
Fall over the run98.4 ft x 1%11.8 in drop
Depth at the inletas entered29.5 in
Depth at the outlet29.5 in + 11.8 in41.3 in
Mean depth(29.5 + 41.3) / 235.4 in

Step 2 — Excavation

The trench volume uses the mean depth, not the depth entered — which is the difference between this calculator and a constant-depth estimate.

CalculationFormula / SubstitutionResult
Trench volume11.8 in x 98.4 ft x 35.4 in10.59 cu yd (8.1 cu m)
A constant-depth sum would give11.8 in x 98.4 ft x 29.5 in8.83 cu yd
Dig the fall adds10.59 - 8.83 cu yd1.77 cu yd (20% more)
Spoil to move10.59 cu yd x (1 + 25%)13.24 cu yd loose

Step 3 — Drainage stone

The cap layer comes off the top of the trench and the pipe displaces stone from within it; what is left is the stone to order.

CalculationFormula / SubstitutionResult
Cap taken off the top35.4 in - 3.9 in31.5 in of stone
Stone in the trenchstone envelope less the pipe243.9 cu ft
Order volume243.9 cu ft x (1 + 5%)9.48 cu yd (7.25 cu m)
Weight to order256.1 cu ft x 94.9 lb/cu ft12.15 US tons (11.02 tonnes)
Water held in the voids243.9 cu ft x 40%97.6 cu ft (730 gal)

Step 4 — Pipe, cover and fittings

Cover over the pipe is what is left after the cap and the bedding, and it grows toward the outlet. Pipe is packed into whole coils or sticks, never divided.

CalculationFormula / SubstitutionResult
Cover at the inlet29.5 in - cap - bedding - 4.4 in pipe18 in
Cover at the outlet41.3 in - cap - bedding - 4.4 in pipe29.9 in
Perforated pipe laid1 run98.4 ft (30 m)
Pipe to buypacked into 50 m coil1 coil
Solid outlet pipe9.8 ft off 10 ft stick (rigid)1 x 10 ft stick (rigid)
Fittings1 cap, 0 tees, 1 coupling3 pieces

Step 5 — Geotextile

The wrapped section is what the fabric has to cover across the trench, measured at the deepest end. If it exceeds the roll width, the fabric is seamed lengthwise.

CalculationFormula / SubstitutionResult
Section to cover(2 x 11.8 in) + (2 x stone depth) + 11.8 in overlap9.19 ft (2.8 m)
Strips off the roll1 + ceil((9.19 - 6.56) / (6.56 - 0.98))2 strips, 1 seam
Rolls to buystrip lengths packed into 328.1 ft rolls1 x 2 m x 100 m roll

Step 6 — Capacity check

The water arriving is sized against what the pipe can carry away at the flattest run's grade, and against what the stone can hold while that happens.

CalculationFormula / SubstitutionResult
Design inflow0.55 x 0.79 in/hr x 0.0494 acres9.6 gpm (0.61 l/s)
Pipe capacity, full boreManning at n = 0.024, 1%44.4 gpm
Usable capacity44.4 gpm x 50%22.2 gpm
Pipe running at9.6 / 44.4 gpm21.6% of full — comfortable
Storage buffer97.6 cu ft / 9.6 gpm76 minutes of the design inflow

Therefore, this drain needs 10.59 cu yd of excavation and 12.15 US tons (11.02 tonnes) of clean angular 20-40 mm stone, 1 x 50 m coil of 100 mm perforated pipe, 1 x 2 m x 100 m roll of geotextile and 3 fittings, with 13.24 cu yd of loose spoil to move. The pipe carries the design storm at 21.6% of full bore, with room to spare.

Disclaimer: This calculator provides approximate results for planning and estimation purposes only. Actual requirements may vary based on site conditions, materials, workmanship, and local building regulations. Always consult a qualified engineer, architect, or construction professional before making final decisions.

Frequently Asked Questions

80 mm and 100 mm cover most domestic and small agricultural work, with 160 mm reserved for mains collecting several laterals. As with any drain, the honest answer depends on the catchment and the fall rather than on habit — capacity rises with diameter to the power of 8/3, so 100 mm carries roughly 80% more than 80 mm at the same gradient. Coils come in 25, 50, 100 and 150 m lengths, and because each run has to be one continuous length, the number of coils is a cutting problem rather than a total divided by a coil length.
For a 300 mm wide trench 750 mm deep, about 0.22 m³ per metre of run before the pipe and any cap are taken off — roughly 0.3 tonnes of clean 20-40 mm stone. But that figure only holds at a constant depth. On level ground the fall is dug in, so a 30 m run at 1% averages 900 mm deep rather than 750 mm, and the real requirement is about 20% higher than the per-metre rule of thumb suggests.